TEFKOT make under floor heating cables are available in various wattage ratings, ranging from 150 Watts
to 3000 Watts, with or without shield ( Refer table T1, T2).

SALIENT  FEATURES:

  • PTFE Insulation : PTFE Insulation over the conductor element prevents it from thermal aging. The life of the wire once laid is as long as life of the Building.

  • Maintenance Free: Electrical under floor heating cables are maintenance free as they do not have any moving part as compared to hydronic systems which have valves etc requiring maintenance from time to time. Also tubes in hydronic system get blocked due to contamination and needs periodic replacement  .

  • Very thin: Diameter of cable is thinner than the diameter of cable with other insulations like PVC etc. It makes the laying very easy . Nominal diameter of the cable is as small as 1.2 mm for unshielded and 2.4 mm for shielded cable. This factor minimizes the rise of floor level during installation.

  • Moisture resistant: Shielded PTFE insulated heating cables are specially designed for working in places that are prone to moisture, like Bathrooms, etc.

  • Operating Voltage: Under floor heating cables are designed for operating voltage of 230 V AC/RMS .( Cable can be designed and manufactured for any voltage rating).

  • Linear Wattage: TEFKOT make under floor heating cables are made in 10 Watts/Lin.meter for shielded cables and 12 Watts/Lin.meter for unshielded cables. ( Cables with different Linear wattages can also be designed as per customers request).

  • Cost effective: Prices of TEFKOT make under floor heating cables are internationally most competitive.

  • Application: Under floor, Under tile, under carpet heating systems.

  • Other Applications: Custom made heating cables can be manufactured for use in car seat heating , heated towel rails, heating blankets, soil warming, water pipe warming, snow melting applications etc. Please send us your specifications and we would be pleased to design cables as per your specifications.

 

STANDARD UNDER FLOOR HEATING CABLES :

(System Voltage: 230 Volts AC/RMS)

Table T1 : UNSHIELDED CABLE (12 Watts/Lin.Mtr) .

S.No.

WATTS OF ELEMENT ELEMENT LENGTH

WATTS/Lin.M.

OHMS/M TOTAL OHMS Amps
1 150 12.5 11.99 28.222 352.775 0.652
2 275 23 11.94 8.373 192.577 1.194
3 380 32 11.94 4.329 138.53 1.66
4 500 42 11.86 2.528 106.176 2.166
5 750 63 12.00 1.11 69.97 3.289
6 1000 83 12.06 0.6366 52.8378 4.353
7 1250 105 11.90 0.4031 42.330 5.434
8 1500 125 12.00 0.2820 35.245 6.526
9 1750 147 11.94 0.2051 30.144 7.630
10 2000 167 11.95 0.1587 26.510 8.676
11 2500 208 12.01 0.1018 21.183 10.858
12 3000 250 12.01 0.0705 17.618 13.055
TABLE - T1
 

 

 

  Table T2: SHIELDED CABLE (10 Watts/Lin.Mtr) .

S.No.

WATTS OF ELEMENT ELEMENT LENGTH

WATTS/Lin.M.

OHMS/M TOTAL OHMS Amps
1 150 15 9.97 22.9 343.5 0.66
2 275 27.5 10.06 6.953 191.194 1.20
3 380 38.5 9.9 3.605 138.79 1.66
4 500 50 9.94 2.13 106.5 2.16
5 750 75 10.02 0.939 70.425 3.27
6 1000 100 10.04 0.527 52.695 4.37
7 1250 125 9.97 0.340 42.462 5.42
8 1500 150 9.97 0.236 35.583 6.50
9 1750 174 10.05 0.174 30.252 7.60
10 2000 199 10.03 0.133 26.5 8.68
11 2500 249 10.05 0.085 21.145 10.88
12 3000 299 10.03 0.059 17.642 13.04
TABLE - T2

 